IKE FUZI PABX PBX telephone switching system set readme manual

Support telphone:86-024-23884705

Table of Contents

  1. Brief Introduction and Features
    • Introduction of TC-2000 System
    • Fundamental Technical Information
    • The internal structure
    • Operating Principle
    • Features & Specifications
    • System Features of TC-2000 Series
    • Specifications
  2. Installation & Connection
    • Before installation
    • Safety instllation instructions
    • Installation precautions
    • Structural connection
    • Name of parts
    • Connecting procedures
  3. System Programming
    • Remarks
    • Unlocking Programming Password
    • CO line ringing assignment
    • Setting the operating mode
    • OGM recording
    • Music on-holding
    • Set CO Line
    • Assign Flash time for Call transfer
    • Assign dial-out mode for extension
    • Assign CO line to exclusive extension
    • Extension class assignment
    • Setting restriction class
    • Call duration control
    • Flexible coding
    • Return to system default settings
    • The default setting for TC-2000 Series
  4. Operating Instruction
    • Outward dialing directly
    • Outward dialing by dialing "0" first
    • Outward dialing by patting hook
    • Outward dialing by a exclusive line
    • Intercom calling
    • Answering call
    • Call transfer
    • Boss/Secretary function
    • Conference
    • Call pick up
    • Call Forwarding
    • Automatic reporting of extension number
    • Priority access and monitoring
    • Doorbell & Door lock
    • Connection instruction
    • Ringing extension assignment
    • Answering the call
    • Doorphone call pickup
    • To open the lock
    • Assign Monitor & Recorder
    • Assign certain C.O line be monitored

      Appendix

      • Doorbell
      • Door-opener
      • Telephone Recorder
  5. Maintenance & Troubleshooting
    • Outgoing calls cann`t be made
    • Outside calls cann`t dial in
    • Intercom cann`t be made
  6. Warranty
  7. Appendix

    Index of system programming

  1. Chapter 1 Brief Introdution & Features

    Introduction to TC-2000 system

    TC-2000 Seires System is "Private Branch Exchange"(abbreviated as PBX), which is a Telephone System that switches calls between users on internal telephone lines while allowing other users to share a certain number of external telephone lines

    Fundamental Technical Information:

    We integrate in this model special-purpose telecommunication ICs from American & Japanese companies, for lower energy consumption, small size, compact appearance, disturbance resistance, high reliability, simple installation andprogramming.

    The internal structure

    Master control system

    1. CPU is composed microprocessor, SDRAM and series-parallel conversion circuit.
    2. DID/DTMF is composed circuits of auto-attendant, music generating, signal tone generating and audio decoding circuit.
    3. EXT.is composed of ringing testing circuit, contra-polar testing circuit and system multi-function testing circuit.
    4. Voice volume amplifying system, which is made of patented amplifying module that enormously, improves thecommunication quality.

      Extension system

    5. Extension pick-up & hang-up testing circuit
    6. Special thunder-strike-discharging circuit & buffer circuit
    7. Signal exchanging matrix circuit

      Power control system

    8. DC48v
    9. AC65v ringing current generating circuit

    Operating Principle

    The structure and its operating principle are shown in the following graph.

    CO Line, thunder-strike resistance, constant current load, signal exchange matrix, signal tone, ringing testing,DTMF decoding, memory, CPU, pick-up and hang-up testing, extension, constant current source, ringing activator.

    Operating Principle

    Features and Specifications

    The TC-2000 Series are designed to provide a family and small office with low cost professional telecom service.The maximum capacity is 1 to 6 CO lines and 8 to 32 Extensions.

    The Auto-Attendant Service (DISA: Direct Inward System Access) with OGM (Outgoing Message service) allows the system to make the Maximum use of the CO line.

    System Features of TC-2000 Series

    There are number of supplementary features to indicate quality of TC-2000 Series System

    OGM Recording with DISA(Auto-attendant)

    Call Transfer & Call pickup

    music on holding

    Ringing Assignment

    Flexible Coding

    Seven Level Call Restriction

    Call duration control

    Automatic distinguishes CO Lines

    Power Failure Transfer

    Three way conference

    Intercom dialing

    Multiple communication lines

    Caller ID

    Call Forwarding

    Doorbell and door lock

    Monitor and recorder

    Specifications

    1. Capacity: CO Lines: 1 to 6

      Extensions: 8 to 32

    2. Exterior sockets: Conjunction for extensions,
    3. Communication lines: 7
    4. Transmission attributes: Extension to extension 1.5dB;
      Extension to trunk line 2.0dB;
    5. Ringing current: 65v/50Hz;
    6. Feeding current: 48v-60v/25mA;
    7. Relative unbalance againstground:300Hz-600Hz 40dB;
      600Hz-3400Hz 46dB;
    8. Dialingmode: DTMF
    9. Signal tone:
      • CO Line: tone from local telephone company;
      • Internal dialing tone: 450Hz, continuous wave;
      • Extension echo signal: 450Hz,1 secondon and 4 seconds off;
      • Extension busy signal: 450Hz,0.3second on, 0.3 second off;
      • Extension confirmation signal: 450Hz,1 second on;
      • Extension error signal: 450Hz,0.3second on, 0.3 second off ;
    10. Power supply:AC220V/110V10% Power consumption: 15VA
    11. Operational environment: Temperature: 32F-104F(0C-40 C);

      Relative humidity 90%

    4 page

  2. Installation & Connection

    Before Installation

    For easy and quick installation and connection, it is strongly recommended that the user read and follow the following instruction carefully so as not to damage the system accidentally by incorrect operation.

    Safety Installation Instructions

    When installing telephone wires, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons. Including the following:

    1. Never install telephone wires during a lighting storm.
    2. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations.
    3. Never touch UN-insulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.
    4. Use caution when installing or modifying telephone lines.

    Installation precautions

    This set is exclusively made for wall mounting or set on desk. Avoid installing in the following places (Doing so may result in malfunction, noise, or discoloration).

    1. In direct sunlight, hot, cold, or humid places. (Temperature range: 0 C-40 C / 32F-104F)
    2. Places in which shocks or vibrations are frequent or strong.
    3. Dusty places, or places where water or oil may come into contact with the unit.
    4. Near high-frequency generating devices such as sewing machines or electric welders.
    5. On or near computers, telexes, or other office equipment, as well as microwave ovens or air conditioners ( It is preferable not to install in the same room with the above equipment).
    6. Install at least 6 feet from radios and televisions.
    7. Do not obstruct area around the main unit (for reasons of maintenance and inspection be especially careful to allowspace for cooling above and at the sides of the main unit).

    Power Failure

    In the event of power fialure, CO.1 to CO.4 will be connected to EXT.801--804 automatically. But CO.5 & CO.6 can`t be used for 6 CO line unit.

    Call ID

    FSK/DTMF compatible Caller ID function is successfully equipped on TC-2000 system. The steps are as below:

    1. Go to your telecom office applying the Caller ID service.
    2. Extension 801-808 can realize the caller ID function.
    3. An incoming call number will be displayed on the phone with Caller ID function. But the number will disapper when you transfer the call to another extension.
    4. For some area the Caller ID function is invalid because of the Telecom Singal of the area.

    Structural connection:

    Structural connection
  3. System Programming
    1. Remarks
        1. All the function setting must be carried out on extension 801 and un-lock first;
        2. All the extensions must be of double tone;
        3. Press * to start setting and press # to end the setting. You don`t have to hang up if something wrong occurs during the setting. You may restart the setting by simply pressing * again;
        4. If extension 801 is in direct dialing out mode, you need to press * to enter the internal system, and press itagain to start programming;
        5. When the setting is finished, a long beep indicates that the setting is done correctly and saved in the system.If instead an array of short chirps is heard,that would indicate an error occurred in the setting. You need to check it out and reset the system;
        6. All the setting involved multiple users can be carried out in a batch process mode. It will surely increase the speed and accuracy of the setting.
      1. Un-locking Programming Password

        Format: * 01 abcd #

        Explanation: abcd is the password.

      2. Changing the Password

        Format: * 02 abcd #

        Explanation: abcd is the new password.

    2. CO Line Ringing Assignment

      Format: * 1 m abcd #

      1. Setting the operating mode

        Format: * 2 1 #

      2. Set Auto-Attendant (OGM)
      3. OGM Recording
      4. OGM Play
      5. Music on-holding
      6. The DISA optional:
      7. Set CO Line
    3. Assign Flash time for Call transfer
    4. Assign dial-out mode for extension
      1. Direct Dial out
      2. Resetting Direct Dial mode
    5. Assign CO line to Exclusive Extension
      1. Assign CO line to be exclusively accessed by certain extension(s)
      2. Assign Extension to CO
    6. Extension Class Assignment
      1. Assign calling class for certain extension
      2. Assign calling class for all extensions
    7. Setting Restriction Group
      1. Setting leading digits for class "n"
      2. Clear leading digits for class "n"
      3. Assign Special Calling number
      4. Clear the function
    8. Call Duration Control
      1. Setting call duration for extension
      2. Clear call duration control
    9. Flexible coding
      1. Extension Number Assignment
      2. Restoring Original Extension Numbers
    10. Return to System Default Settings

      The default setting for TC-2000 series:

      Operating mode: Operator mode

      Ringing extension: 801 to 804

      External lines: 1 to 6

      Trunk line grouping: not set

      Outgoing class: 1

      Restrict outgoing digits: No

      Original EXT number: 801 to 832

      Dialing out mode: Dial "0" or patting hook for outgoing calls

  4. Operating Instruction
    1. Outward Dialing

      This system provides 4 dialing modes to meet the different need of customers: direct dialing out, patting hook dialing out, direct out by dialing "0" first and dialing out by a special line.

      1. Outward Dialing directly
      2. Outward dialing by dialing 0 first
      3. Outward dialing by patting hook
      4. Outward dialing by a exclusive line
    2. Intercom calling
      1. Intercom calling at direct outward mode

        Format: * + Extension number

      2. Intercom calling at in-direct outward mode

        Format: Dial the extension number directly.

    3. Answering call
      1. Answering calls at operator mode
      2. OGM mode answering calls
    4. Call transfer

      Format: Pat the hook then dial the extension number

      Description: Allows you to transfer an incoming call to another extension.

    5. Boss/Secretary Function

      Format: Pat the hook then dial the extension number

      Description: This funciton let you make an outgoing call from one extension then divert and connect other extension to CO line.

    6. Conference
      1. Conference (1 CO line and 2 extensions)

        Format: Pat the hook and * and extension number

        Description: Allows you to add a third party to a two-party conversation and make a three-party comference. You can have only two extensions with one CO line.

      2. Caller on holding
    7. Call pick up
      1. Call pick up at extension with direct dialing mode
      2. Call pick up at extension with in-direct dialing mode
    8. Call Forwarding
      1. Setting Call Forwarding
      2. Canceling the setting
    9. Automatic reporting of extension number
    10. Priority access and monitoring
    11. DoorBell & Door Lock
    12. Assign Monitor &Recor
      1. Assign certain extension be monitored
      2. Cancel all monitored Extensions
      3. Assign certain C.O line be monitored
      4. Cancel the function
  5. Maintenance & Troubleshooting
  6. Warranty
  7. Index of system programming